Zcu102 ethernet

Zcu102 ethernet. Can you have a look at the attached zip. I would like to setup my board to have 2x 1G ethernet ports (one for input, one for output, un-synchronized). Set up the Xilinx Zynq UltraScale+ MPSoC ZCU102 evaluation kit as shown in the figure below. 2-final. 1 version. Board ------------------ ZCU102 version 1. ZCU102 lwIP client. 2 image generated with my hdf file (Vivado 2017. 10G on ZCU111 in loopback works fine. Zynq Ultrascale Fixed Link PS Ethernet Demo. 25 MHz (using the onboard Programmable User MGT Clock default freq) Run make program to program the ZCU102 board with Vivado. 1. PNG. This repository replaces XAPP1305. U-BOOT for zcu102. This connector uses a PS-GEM3 eth link shown in Figure-1 in Xapp1306. The interfaces would be as follows: 1) Ethernet controller (GEM3) connects the on-board TI PHY through MIO pins using the RGMII interface. Edited: Removed MSP_Updater. GT subcore in example design. Tcl 48 29. Part Number: EK-U1-ZCU104-G. The ZCU102 Si570 MGT clock is set with SCUI to 156. 740. 0 Board: Xilinx ZynqMP Bootmode: JTAG_MODE Net: ZYNQ GEM: ff0e0000, phyaddr c, interface rgmii-id eth0: ethernet@ff0e0000 U-BOOT for xilinx-zcu102-2018_1 BOOTP GEM3 on ZCU102 Rev1. 5G Ethernet Subsystem IP reference design. Observe kernel and serial console messages on your terminal. 1 board I also had the RAM issue, but I solved it by setting the target board in vivado to the zcu102 and letting it run the IP upgrade. ethernet: failed to add PM domain domain10: -13. eth0: Ethernet FMC Port 0. 22 followers. 10G between two ZCU102 boards works fine. 1. 2 with Vivado 2018. (use the first ttyUSB or COM port registed) All Here's our situation now -. Dec 9, 2021 · My version of the ZCU102 already starts with the right clock frequency (156. AC power adapter (12 VDC) USB Type-A to USB Micro cable (for UART communications) USB micro cable for programming and debugging via USB-Micro JTAG connection. to open a UDP connection to port 1234. i followed these links to make all binaries https://xilinx-wiki. VCK190-Boot Public. 10GBASE-R SFP \+ SMF in loopback. boot-cpu="rpu-cpu[0]" ETHERNET; VIDEO; DSP IP Dec 15, 2020 · Figure 1: Zynq UltraScale+ MPSoC Ethernet Interface Note: The PS-GEM3 is always tied to the TI RGMII PHY on the ZCU102 evaluation board. zcu102_10g_ethernet_CSO: This directory contains the PetaLinux recipes and metadata of the checksum offload design. 1: See Answer Record (Xilinx Answer 69769) PetaLinux - Zynq MPSoC PS-GTR SGMII - fixed link support patch: 2017. 5G Ethernet subsystem IP core [Ref 1]. sh. I started by creating a project via the available 2021. We want to confirm the TX/RX Checksum offloading is These reference designs can be used with the stand-alone lwIP echo server application template that is part of Vitis; however, some modifications are required. And ifconfig eth0 down and up to bring up the ethernet interface. 5G Ethernet PCS/PMA or SGMII core used as the physical media Feb 12, 2024 · Video 268190uoyil780 March 19, 2024 at 3:07 AM. I attach the block diagram I am using. This is based on the bsp being used (in your case ZCU102) in which gem0 are not enabled. I have been reading through the ZCU102 TRM about ethernet. I built a design for the ZCU208 similar to the pl_eth_10g design for the ZCU102. 4 PetaLinux - MIO Ethernet does not work on ZCU102 RevB boards with the 2015. So, my assumption is that the default Ethernet Subsystem's configuration after reset is just right for me. Ethernet cable to connect target board with host machine. bat). ls /dev/ output: clocks. root@farzian:~ # echo 1 > /sys/bus/pci/rescan. After the petalinux is booted successfully, it seems the OS does not recognized the device (ZC706). When the petalinux project is created with the zynqMP template the xxv_ethernet works correctly. Number of Views 65 Number of Likes 0 Number of Comments 4. 25 MHz as expected. 01 Xilinx ZynqMP ZCU102 rev1. Core configuration: 10G Ethernet MAC \+ PCS/PMA 64-bit - BASE-R. Buy. Hi, I am running Petalinux on the ZCU102 with Xen. 3: See Answer Record (Xilinx Answer 71168) Zynq UltraScale+ MPSoC - PS GEM Flow Control limitation: 2018. SD-MMC flash card for Linux booting. Configure ZCU102 for SD BOOT (mode SW6 [4:1] switch in the position OFF,OFF,OFF,ON as seen in the below picture). No ethernet found. there is a tutorial on how to use the 10G AXI Ethernet on the ZCU102. The lwIP library needs some modifications to be able to properly configure the Marvell PHYs (88E1510) that are on the Ethernet FMC. qemu-system-aarch64 -M xlnx-zcu102 -smp 6 -serial stdio -device loader,file=app. ip neighbor show doesn't return anything. software-prototypes Public. Any help will be appreciated highly Environment info: ------------------------- 1. 0 (uname -a)). Last updated: Apr 24, 2023 by William Cassells. In the Vivado directory, you will find multiple batch files (*. 2). 2, but should still help The Zynq UltraScale+ MPSoC Base Targeted Reference Design (TRD) is an embedded video processing application running on a combination of APU (SMP Linux), RPU (bare-metal) and PL. This will generate a Vivado project for your hardware platform. The Vitis directory of the source repository contains The board is Zynq ultra-scale + (ZCU102- xczu9eg). I would like to use the GEM3 on my ZCU102 board. I'm still having trouble with the 1G Ethernet PCS/PMA core. But in the software, there is no such file. to use this 10G ethernet IP, i need a driver. 4 for our design to be run on ZCU102 board. 7 min read. Create the PetaLinux ZynqMP project: BSP Flow: petalinux-create -t project -s xilinx-zcu102-v2019. 00. The ZCU104 Evaluation Kit enables designers to jumpstart designs for video conferencing, surveillance, Advanced Driver Assisted Systems (ADAS) and streaming and encoding applications. 00 MHz (using the onboard CLK_125_P/N and routing it to a IBUFDS primitive to obtain "dclk") Connect USB UART J83 (Micro USB) to your host PC. eth2: Ethernet FMC Port 3. Hi, I am stuck with Ethernet issue for a long time. 1? ZCU102 PS and PL based 1G/10G Ethernet v2019. 5, 18. The design supports the following video interfaces: Sources (blue): Virtual video device (vivid) implemented purely in software. If you are looking 1Gbps ethernet data trasfer, then please use RJ45/P12 connector over the ZCU102 board. 10G on ZCU102 in loopback works fine. At this moment, I have the IP core configured for 1000BASE-X with "processor features" disabled, but I am not 100% sure whether I need the features available in processor mode or not. Ehternet is not detected in any linux image (Like TRD image) & can not use ethernet. I have a Zynq ZC706 design that I'm porting to the ZCU102. I did ifconfig and I only see loopback and SIT ports. Ethernet FMC Port 2 is unusable in this design. 0 can't connect to phy. 2 (linux version =4. This means that it only supports this two specific versions or it supports from 16. I am trying to initialize the 10G/25G Ethernet Subsystem IP without using any axis port or Zynq Processor. PS Gem3 of ZCU102 is successfully up, however, when I am trying to add the follwoing in system-user. Apr 24, 2023 · Networking in QEMU. From the images, you can see that one hardware clock has been attached to both ethernet ports. Connect one end of Ethernet cable into the ZCU102 connector J73, and other end connect to the Ethernet socket of the host machine. See page 41 of the ZCU102 schematics on page 41. You can use ifconfig to set ip address and gateway etc. It is also possible to use hping to test the design by running. can be used to send a huge amount of data. . Case 02: I enabled static IP without DHCP. 5G Ethernet Subsystem" IP Core only on the PL side of the KCU105 board I have. It seems that this driver is not part of the current linux kernel that i have built using petalinux 2019. Hello i am trying to use 10G ethernet on zcu102 with petalinux 2020. com/Xilinx-Wiki-Projects/ZCU102-Ethernet/blob Double click on the batch file that is appropriate to your hardware, for example, double-click build-zcu102. 92K views; You can find 10G example based on ZCU102 here: Jul 5, 2017 · U-BOOT for zcu102 Ehternet is not detected in any linux image (Like TRD image) & can not use ethernet. atlassian. 25MHz, GT DRP clock - 100MHz. This will generate a Vivado project for your hardware platform. Run Vivado and open the project that was just created. ZCU102 Petalinux 2021. 3 Feb 24, 2021 · U-Boot 2018. Jun 17, 2016 · That makes it awesome for Ethernet applications which is why I’ve just developed and shared an example design for the Zynq Ultrascale+ ZCU102 Evaluation board, armed with an Ethernet FMC to break-out those handy GEMs. I am not really sure about every connection, so please advice me if anybody find an issue. net/wiki/spaces/A/pages/18841830/PS+and+PL+based+Ethernet+in+Zynq+MPSoC and to modify system-user. When the bitstream is successfully generated, select File PC to ZCU102 Ethernet connection. There's no boot log messages for this Network load 10%. 1-final. 谢谢!. 0. Again you have not mentioned which Ethernet speed, I am assuming Gigabit or less, hence suggesting you the TEMAC core. Please follow this page for the PS DDR related changes to be made in the github design. Hello, I'm working with the ZCU102 Evaluation Board. ip link show says the Network eth0 is UP 3. 嵌入式开发. The ZCU102 board has two FMC connectors, both high-pin-count (HPC), so I’ve created one basic design with two sets of 66367 - 2015. This was created in 2016. 5. Hello All I am trying to implement an application where the PS Ethernet port of ZCU102 (Gem 3) is connected to PC and this data form PS Ethernet is forwarded to PL Ethernet of ZCU102 and the same is communicated to other ZCU102 board. elf,cpu-num=4 -global xlnx,zynqmp. 5V. Reload to refresh your session. I use the default hardware of the bsp to build the petalinux project and I run it with an SD card. To demo this, the GEM2 is routed to the GEM3 via the PL. Anyways, all Ethernet IP cores come with an example-design which helps the IP core users to understand how to use it. 4. (I have reference documents XAPP1305 Ethernet Subsystem) I create a project to implement loopback on 2 SFP+ ports of the board, with IP Core Trans_Rev_Data_10G is responsible for pushing ethernet packet II to Port 0 and loopback to port 2 (image ZCU102 Rev1 evaluation board. x: See Answer Record (Xilinx Answer 69132) I am using ZCU102 Board. My problem is that I am not able to make an ethernet connection between the PC and the board. Double click on the batch file that is appropriate to your hardware,for example, double-click build-zcu102. LVDS is required to receive the Ethernet FMC’s 125MHz clock. After generating an image from petalinux 2017. GTH. 3. For example, this may include an Ethernet PHY device node and I2C extender nodes for the ZCU102. Owned by Joe Komlodi. 2) PS Ethernet block GEM0 with the PL PHY through the EMIO interface. I am stuck with Ethernet issue but Ethernet is a must in my application. 2, but should still help To detect PL Ethernet in ZCU102. This cable will be used for UART over USB communication. KCU105 LPC eth0: Ethernet FMC Port 0. In order to include this BSP support, you need to set the YAML_DT_BOARD_FLAGS flag for your target either in a machine configuration or in a device-tree. The idea is to establish contact between PL and PS of 2 Boards. 1 ethernet. Check out the introduction/first part if you are Board Component Descriptions 10/100/1000 MHz Tri-Speed Ethernet PHY [Figure 2-1, callout 12] The ZCU102 board uses the TIDP83867IRPAP Ethernet RGMII PHY [Ref 18] at U98 for Ethernet communications at 10 Mb/s, 100 Mb/s, or 1000 Mb/s. This interface uses the 1G/2. 4 PetaLinux ZCU102 BSP Number of Views 593 47113 - 13. Additionally, I routed out gtrefclk from the 10G core to an LED line so I can verify that it is indeed coming into the GT differential • ZCU102 Rev1 evaluation board • AC power adapter (12 VDC) • USB Type-A to USB Micro cable (for UART communications) • USB Micro cable for programming and debugging via USB-Micro JTAG connection • SD-MMC flash card for Linux booting • Ethernet cable to connect target board with host machine ZCU102. Device Support: ZCU102 Board Setup: 1. Connect USB UART J83 (Micro USB) to your host PC. But, i'm trying to make it works on my PetaLinux 2017. Any text entered into netcat will be echoed back after pressing enter. One difference between the IP in the designs is that in the ZC706 there was a gtrefclk_bufg_out output whereas this output doesn't exist in the ZCU102 version. One thing to be wary of is that you either have to apply the clocking patch like or change the reference frequency to 156. + 4. There is an issue when I try to define IIO over ethernet it asks me for a file that is tcp_socket. Through clocking wizard, 75 MHz is passed to dclk, and processor reset IP (external reset is connected to system reset (Ethernet zcu102 10G driver. I am trying to use PS GEM3 and PL !G of ZCU102. Turn on the power switch on the FPGA board. You signed out in another tab or window. We are not seeing the ethernet being detected. If needed, we can send you the steps of updating firmware to you via email or EZmove, that would have some instructions on how to update the MSP430 firmware on ZCU102. 128 -2 -p 1234 -d 1024. 3). It has the xxv_ethernet in the PL and GEM3 enabled in the PS. pl_eth_1g - PL 1000BASE-X design utilizing the AXI Ethernet 1G/2. 1 bsp for the ZCU102, editing only the static IP address (instead of DHCP). Verilog Ethernet components for The reference design link is as follows. It runs correctly. A high-level block diagram is shown below. 8V and 2. dtsi file from. ZCU102 評価キットでは、オートモーティブ、産業、ビデオ、および通信アプリケーション向けデザインを素早く完成させることが可能です。. ZCU102 SFP and 1G/2. Sep 13, 2022 · The top-level directory structure is described below: PetaLinux: This directory contains PetaLinux recipes and metadata to build the images for the two use cases. Ethernet LED (DS27), LED_0 and LED_2 of RJ45 jack is always off though blink once at powerup time. I'm proceeding with a 1G design for now with the hope that I hear something about 10G at which point I'll upgrade my design. The design includes the PCS/PMA IP which is connected to an SFP port on the board. b) If using pre-built PetaLinux images: Halt at U-Boot, and issue the following commands: ZynqMP> setenv ethaddr ZynqMP> saveenv . リードタイム: 8 週間. I am using the IIO support over the UART terminal in my design but I want to move over ethernet. I am designing a custom board that is based on Xilinx's ZCU102 development board and have a question regarding the DP838671IR Ethernet PHY strapping pins. 0 I2C: ready DRAM: 4 GiB EL Level: EL2 Chip ID: zuunknow ** Bad device mmc 0 ** Using default environment In: serial@ff000000 Out: serial@ff000000 Err: serial@ff000000 Model: ZynqMP ZCU102 Rev1. 816746] macb ff0e0000. [ 48. This repository contains ZCU102 design files for PS and PL based 1G/10G Ethernet. 2 project to 2021. ifconfig says eth0 is UP, however there is no RX packets. com. T hat has now been replaced with updated Sorry for bothering again but I already have an evaluation license to run the AXI 1G/2. inet addr:127. So I prevented the clock from being re-configured during boot by editing the device tree. ethernet eth0: DMA bus error: HRESP not OK ZCU102 SFP and 1G/2. h. I use 10G/25G ethernet subsystem IP for PCS/PMA part. 25MHz in the Ethernet core, since that's what the ZCU102 defaults to. 3 XAPP1305 - 1G PS EMIO Ethernet/PS EMIO SGMII reference designs need patch: 2017. Hi all, I am trying to transmit packets via 1GE/SFP on the ZCU102. This application note focuses on Ethernet-based designs that use Zynq® UltraScale+™ devices. United States of America. An ILA check shows the clock instant that corresponds to /dev/ptp0 gets updated when ptp4l starts running. Monitor with DisplayPort (DP) capability and at least 1080P The PS can pretty easily use the SFPs as 10G Ethernet interfaces (there is a ZCU102 reference design for this). Price: $1,678. eth2: Ethernet FMC Port 2. 価格: $3,234. I am not sure if I need the "processor features/mode" available in the AXI 1G Ethernet Subsystem. No Ethernet in PetaLinux 2017. . 10G between two ZCU111 boards works fine. bsp. The board supports RGMII mode only. I am in need of some tutorial or links, which are useful to learn bare metal based Ethernet on ZCU102 kit. GT subcore in core. To sendding data over ethernet port is what is descripbed in Xilinx Application Note. Hello Friends, I am currently working on a simple Baremetal TCP client using the lwIP stack. dtsi https://github. 2. So we rebuild the PetaLinux system image in ZCU102. ZCU102 Ethernet PHY strap configuration resistors. This page previously contained information to augment XAPP1305 & XAPP1306, providing updates for new versions, performance metrics, etc. hping 192. Port fpga-zynq (rocket-chip) to Xilinx ZYNQ Ultrascale+ board (ZCU102) ethernet mpsoc sfp zcu102 fastoptics optics-communication Updated Jun 26, 2023; VHDL May 31, 2019 · AMD / Xilinx MPSoC ZCU102 Evaluation Kit features a Zynq UltraScale+ MPSoC device with a quad-core Arm® Cortex-A53, dual-core Cortex-R5 real-time processors, and a Mali-400 MP2 graphics processing unit based on AMD / Xilinx's 16nm FinFET+ programmable logic fabric. The ZCU102 board has two FMC connectors, both high-pin-count (HPC), so I’ve created one basic design with two sets of HW-Z1-ZCU102_REV1_0 12VDC Clock devices Pages 39-41 PS/PL/System 0 HP BANK# PAGE# BANK 0 BANK# PROG. GT subcore in core, GT Refclk - 156. ethtool_1. Nov 10, 2022 · ZCU102 Rev1 evaluation board. Feb 2, 2021 · PS and PL based Ethernet in Zynq MPSoC. bsp". There are 6 available designs: . 1 min read Legacy editor. 2, I could not get linux to use the ethernet on GEM3: u-boot can use the ethernet fine, pinging works, DHCP works: U-Boot 2017. You switched accounts on another tab or window. 5G Ethernet PCS/PMA IP Part 2. Ethernet Example Projects targeting the Xilinx ZCU102 evaluation board. I am using bare metal on ZCU102 kit. I'm also having issues with the ethernet example on 2019. The setup image is attached. When I check the status_vector output of the core it bits 0 and 1 are 0 (indicating the link status and link sync are not good) and bits 5 and 6 are toggling (RXDISPERR and 作成者: AMD. eth1: Ethernet FMC Port 1. It describes the use of the gigabit Ethernet controller (GEM) available in the processing system (PS) through the extended multiplexed I/O (EMIO) and multiplexed I/O (MIO) interfaces. 04. I have built a project of ADRV9009 no-OS on the zcu102 board. ethernet failed with error: -13 . Aug 25, 2022 · Cross-check the MAC ref clock configuration I verified the refclk frquency from the XGUI tool as well as on the board all the way to the C8 FPGA pin via accessible on the back of the board with an oscilloscope. 5G Subsystem. zip from the original reply, since its not officially supported, therefore may not work for everyone. ZCU102 (HPC1) eth0: Ethernet FMC Port 0 (GEM0) eth1: Ethernet FMC Port 1 (GEM1) eth2: Ethernet FMC Port 2 (GEM2) eth3: ZCU102 on-board Ethernet port (GEM3) Example Usage Hi @carol (Member) ,. After Enabling 1588 on the AXI 1G/2. 10G Ethernet/AXI MCDMA Zynq UltraScale+ 1588 hardware time stamping reference design and driver files - Vivado 2018. lo Link encap:Local Loopback. However, when I boot PetaLinux kernel, generated using design's HDF, the etherner link goes UP after ZCU102 board powerup, during FSBL and U-BOOT execution, but goes DOWN somewhere in the middle of kernel boot. and a 1. Make sure to save the new config prior to exiting the GUI menu. 4 EDK [Zynq QEMU] "mmc0: Timeout waiting for hardware interrupt" Enabling PTP with ZCU102 MCDMA AXI Ethernet prevents internet connectivity. Although HR I/Os can support many different I/O standards at 1. ZCU102 Ethernet is not working. Ethernet; Like; Answer; Share; 4 answers; 1. eth3: Ethernet FMC Port 3. Insert SD card into socket. 2), we are no longer able to connect to the ZCU102 using SSH. GT RefClk = 156. bat if you are using the ZCU102. The iptables utility is used here for testing purposes only and are prepended with Opt. 1 on the ZCU102 board and have started with a baseline to ensure things work as expected. デバイス サポート: Zynq UltraScale+ MPSoC. The Kit's ZCU102 Board supports all major peripherals and interfaces, enabling I'm testing the 10G/25G Ethernet Subsystem example design from xapp1305 on the ZCU102, and connecting a SFP+ DAC (direct connect) adapter to a 10GE switch. bbappend . pl_eth_sgmii - PL SGMII design utilizing the AXI Ethernet 1G/2. I learnt that high-speed communications like Ethernet, PCIe, etc. But I don´t have any LOC constraints defined for my ZCU102 board. Figure 1-1: ZCU102 Evaluation Board Block Diagram Prototype Header Display Port Aux MSP430 GPIO IIC0 Connection Pages 44, 56, 38 SYSMON IIC SFP Disables MSP430/CP2108 UART HDMI control Pages 6, 34 PMOD 125MHz CLK Trace IIC1 Connection Pages 54-55, 58 Ethernet USB Pages 51-52 SDIO PMU, GPIO PS Display Port Aux Pages 47, 44-45 FMC HPC1 GT ethool for eth1 has ptp0 as hardware clock. Maybe that is enough of a speed up for your current method of ssh+scp, would probably take less than a day to try. ZCU102-Ethernet Public. 128 1234. I am stuck with Ethernet issue but Ethernet is a must in my 我在使用ZCU102开发板过程中,想要使用SDK中的模板进行LWIP echo server实验,但是失败了好多次,期间也参考过xapp1306,我想问一下怎么才能进行这项实验呢,或者说是怎么设置呢?. Only send TX packets 2. I figure I will make use of the SFP\+ cages provided and use one as an input, and one as an output. Hello everybody, I am using ZCU102, REV1. In this demo, we will demo how to use the fixed link feature in the macb linux driver on the ZCU102 Rev1. ip -br address show doesn't show the IP address. - I use the ZCU102 (zynq ultrascale\+) - Ethernet cable is directly connected to the PC - port is opened in the firewall settings - wireshark is used to analyze the packets I started with the echo_server project. The 1000BASE-X/SGMII PHY and the GTH transceiver are a part of the AXI Ethernet core for 1G PL Ethernet link, which uses the AXI 1G/2. 5G Ethernet Subsystem (7. I'm attempting to migrate an existing petalinux 2020. Control and Status Vectors. When booting to kernel, you can check if Ethernet driver has been correctly probed and then in ifconfig -a , you are able to see all available interfaces. inet6 addr: ::1%4879712/128 Scope:Host. My IP block, largely taken from the TRM, would be something like The FMC connector on this development board connects to HR (high-range) I/Os on the FPGA. The system image provided by the reference design file does not boot when using new DDR DIMMs on ZCU102. 25 MHz), you can check it with the oscilloscope on the ZCU102 on C206-C207 capacitors (bottom of the board). Mar 17, 2022 · IIO over ethernet. Now am going to connect ZC706 and ZCU102 via PCIe slot. I need the measurements of the pcb. I have a problem: i want to use a 10G ethernet IP (BASE-R). By inspecting debug LED status, the IP start with a 10G configuration. source the PetaLinux settings using this command: source <petalinux_installation_path>/ settings. Lead Time: 8 Weeks. Again, this is not g xxv_ethernet design on ZCU208 works with petalinux zynqMP template, but not with BSP. 2. Connect the Micro USB cable into the ZCU102 Board Micro USB port J83, and the other end into an open USB port on the host PC. Feb 20, 2024 · @nanz (AMD) Another question, in the UG1144 it says that the versions of the ubuntu needed to run petalinux are : Ubuntu Linux 16. Configurations I made for this IP are: One core with ethernet PCS/PMA 64-bit (10G), BASE-R, Control and status vectors for the user interface. 5. I ran the "AXI 1G/2. Since I upgraded to Petalinux 2017. 1 (64-bit) . The system boot correctly but the ethernet interface is not detected. 19. I've tried the xapp1305 images and built my own with same exact results. Re-generate the xsa and plnx boot files and verify if the issue persists. 0: PCI bridge to [bus 01-0c] Where is the 10G Ethernet IP Design Assistant? Expand Post. To learn more about the ZCU102 hardware setup, please refer to Xilinx documentation. 10G/25G High Speed Ethernet Subsystem v2. I set a server with iperf3 but if I try to set a You signed in with another tab or window. C 46 35. 25 MHz (using the onboard Programmable User MGT Clock default freq) GT DRP Clock = 125. 0 2. (This example is for a ZCU102 board) Note: the BSP files need to be downloaded from Xilinx. パーツ番号: EK-U1-ZCU102-G. While doing this, I drove using the PHY chip on the board and did the test from the RJ45 input. 4: ZCU102. PicoZed, ZC702, ZC706, ZedBoard, ZCU102, UltraZed-EV eth0: GEM0 to Ethernet port of the dev board Hi, I am working to implement an Ethernet link on ZCU102, by using the 1G/10G/25G Switching Ethernet Subsystem IP version 2. I enabled petalinux-networking in via petalinux-config -c rootfs. We then learned that by default when QEMU boots, it passes a static PM-config object. 5G Ethernet PCS/PMA IP. Hello @martyntyn8 ,. 168. Vivado 2018. Device ID code ------ 24738093 which is Production Silicon 3. 10G ethernet on zcu102. Then run. 2 . I check this by this command. macb ff0b0000. Especially the position of the board connectors on the Evaluation Boards 267174aliemgemg March 7, 2024 at 2:33 PM. I have tested individually and it Works fine. 5V, when it comes to LVDS they only support the LVDS_25 standard which is designed for 2. The top-level directory structure is described below: PetaLinux: This directory contains PetaLinux recipes and metadata to build the images for the two use cases. But 10G/25G Ethernet Subsystem IP is not initialising, and tx_axis_tready is low (0). What is confusing is that the values used for the pull-up and pull-down strapping resistors Ethernet interface is working great when i use "xilinx-zcu102-v2017. Communication between PS and PL ethernet of ZCU102. Hi, zynqmp的zcu102板子经常使用时以太网出现一下LOG,导致linux内核崩溃. Configure the ZCU102 board to boot in SD-boot mode by setting switch SW6 to 1-ON, 2-OFF, 3-OFF, and 4-OFF, as shown in figure below. The ZCU102 can still fetch an IPv4 using DHCP, and ping but cannot utilize wget, SSH, SCP, etc. 01 (Aug 17 2017 - 08:18:24 \+0200) Xilinx ZynqMP ZCU102 rev1. Delete the default value, and keep this empty. Everthing of the board is working fine without Ethernet. Template Flow: Jun 17, 2016 · That makes it awesome for Ethernet applications which is why I’ve just developed and shared an example design for the Zynq Ultrascale+ ZCU102 Evaluation board, armed with an Ethernet FMC to break-out those handy GEMs. 3. I have downloaded the 1G PL Ethernet files from https Currently I am working with the 10G/25G Ethernet Subsystem on the ZCU102 board (Vivado 2018. macb probe of ff0b0000. I have a ZCU102 kit with me and I would like to use Ethernet to send data from the board to PC. 1 Mask:255. Monitor with DisplayPort (DP) capability and at least 1080P Jan 22, 2023 · Add a simple ethernet MAC IP core there (there's a free license for that included in your ZCU102), and send and receive your data as ethernet frames, or add one of the multiple open source UDP/IP or TCP/IP stacks on top, and send IP packets. Click Generate bitstream. netcat -u 192. Hello All. 5 to 18. 2017. Owned by Confluence Wiki Admin (Unlicensed) Last updated: Feb 02, 2021 by Michael McGuirk. Part 2: Connect the AD9082-FMCA-EBZ FMC board to the FPGA carrier HPC0 FMC0 socket. Just like here, I want to drive the phy chip on the board in ZCU102 and use the RJ45 input (RJ45 is not necessary, it can be done using sfp) and I want eth2: Ethernet FMC Port 2 (GEM2) eth3: Ethernet FMC Port 3 (GEM3) Note that the Ethernet port of the dev board in these designs is not connected to any GEM and is thus unusable. 979275] pci 0000:00:00. PB Page 12 Page 22 PAGE# INIT,DONE LEDs GTH228 GTH229 44 48 66 49 50 65 PSDDR 504 BANK 66 BANK 65 MGTH128-130 MGTH228-230 U1 PS 503 BANK 64 64 67 47 12 13 7 3 PS 500 BANK 48 BANK 67 PS 501, 502 BANK 49 PWR CONNECTORS 8 7 8 11 6 11 5 Nov 4, 2019 · This is the second part of the zynq soc gigabit Ethernet series and covers the creation of project in vivado. I made a simple design that just includes a zynq and the core. My assumption was "axi ---> Subsystem AUTO Hardware Settings --> Ethernet Settings --> Ethernet MAC address. gz mf oe wk hx rt mi rx md aj