Profile Log out

Max30102 nodemcu

Max30102 nodemcu. 8V, maximum 2. The MAX30102 sensor is the further optimized version of MAX30100 sensor; used as both a heart rate monitor and a pulse It is easily used with microcontrollers such as Arduino, ESP32, ESP8266 NodeMCU, etc. Bộ đệm FIFO trong cảm biến MAX30102 có thể được cấu hình để lưu trữ từ 32 đến 256 Mar 10, 2021 · #MAX30102 #oximeter #coronavirus #ESP32 #oled #OLED1. The first row displays the beats per minute, and the second row shows the value of the refl Feb 28, 2023 · Based on this environment, a low-cost SpO2 level sensor was developed, which serves as a basis for the implementation of more complex systems and thus introduce the population without technical knowledge to the development of their own sensors, the system is controlled by a NodeMCU open source IoT platform, which is controlling the MAX30102 Step 4: Interfacing MAX30100 Pulse Oximeter With ESP32. In this tutorial, we shall see how we can measure the heartbeat using Maker Nano and max30102, and display it on the OLED display. This library only works for the MAX30102 May 13, 2021 · What's going on under the hood with libraries for NodeMCU, WiFi, etc? PCB Review Request: RGB LED String Controller via NodeMCU ESP8266 Wifi Module: Assigning static IP in nodemcu: Not able to read Interrupt Status Register and reset Interrupts on MAX30102: Help with two-way long-range wireless communication between two ESP32s Aug 16, 2021 · a) MAX30102 Pulse Oximeter: Any MAX30102 sensor will work, but make sure the sensor and the I2C Signals work on the right voltages. Jan 9, 2022 · In this tutorial we will learn to build a Web Server Pulse Oximeter using Nodemcu ESP8266 using MAX 30100 pulse sensor. Internally integrated 18bit ADC, the sensor supports I2C data output, which could be compatible for most controllers. I have used two of the max30102, but it shows the same result. The Circuit assembly for MAX30100 Pulse Oximeter Webserver using NodeMCU is very simple. b) ESP32 NodeMCU Board: Only use ESP32. Subscribed. Board I'm using MAX30102. Login to the Gmail with your Email ID and Password. Therefore, we investigated the use of MAX30102, a commercial photometric biosensing module coupled to a ESP32 system-on-a-chip and its internet-of-things capabilities to continuously gather and process peripheral oxygen levels (SpO2) and heartrates (HR) from users. /example content into your microcontroller. It includes internal LEDs, photodetectors, optical elements, and low-noise electronics with ambient light rejection. Hi, in this tutorial we gonna interface MAX30102: pulse oximetry and heart rate monitor module with Arduino UNO board, and then make a project for measuring BPM using this module + OLED display and a Buzzer. com May 4, 2020 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jan 13, 2021 · The MPU-6050 is an accelerometer and gyroscope. 3 * everytime a heart pulse is detected. For complete project details (schematics + source code), visit https://tutorials. May 21, 2021 · Interfacing MAX30100 with ESP8266 NodeMCU. The Google Docs screen will appear. The MAX30100 Oximeter Sensor works with the I2C bus. The proposed system is equipped with an onboard The ESP8266 module reads raw sensor data from a MAX30102 sensor at 25 samples/second. instagram. UG6409; Rev 0; 3/18 . This sketch will display the BPM and SPO2 values in the serial monitor when you hold the sensor in between your fingers. In this project, you will learn to make an IoT-based Pulse Oximeter using NodeMCU ESP8266, MAX30100, and Blynk Application. We will monitor Heart Rate and oxygen saturation (Sp02) level using MAX30100 sensor. 272. 4. There are many poor-quality boards that do not confirm Maxims specs and will give incorrect values and may not work. While the INT pin is not connected. \n; XD-58C \n; MAX30100 integrated heart rate and pulse oximeter Sep 26, 2021 · I'm try max30102 with nodemcu everything is alright, except the readings I get are changing with a huge different it sometimes give a negative No. The MAX30100 Pulse Oximeter is a medical device that is used to measure blood oxygen saturation levels, heart rate, and pulse strength. Other sensors fail during I2C This is a heart rate monitor made with a max30102 sensor module. We also need to connect the INT or Interrupt pin of the sensor to D2 of the Arduino. 17. The samples are inserted into a circular buffer containing the last 125 samples (5 seconds of readings). 3V. As you can see the VIN and GND pins of the Max30100 sensor are connected with the Arduino’s 3. Apr 25, 2022 · monitor suhu bpm spo2 nodemcu esp8266 sensor mlx90614 dan max30100/30102email = yanuarm@hotmail. Jun 14, 2021 · #arduino #max30102 #oximeterLink to the code and libraries: https://drive. This user guide was developed to help users quickly configure the MAX30101 and MAX30102 devices for pulse-ox and/or heart-rate monitoring use using the MAX30101ACCEVKIT and MAX30102ACCEVKIT. LED Pulse Width: Measure Heart Rate (BPM) and Blood Oxygen Concentration (SPO2) with MAX30100. 4 * It's a modified version of the HeartRate library example. Modified from the SparkFun MAX3010x library. com/drive/folders/1qAQCRKpHryYdSZ8oK2nJpihT4GcQZmuS?usp=sharing Feb 5, 2019 · Wiring of MAX30102 + OLED + Buzzer with Arduino UNO Libraries: If you’re using the module alone download only its library (The first one), the other two are for the OLED display used in the project. 1 /* This code works with MAX30102 + 128x32 OLED i2c + Buzzer and Arduino UNO. Mar 1, 2024 · Connecting the MAX30102 Pulse Oximeterto the microcontroller is really simple. In this guide, we will focus on RCWL-0530 as it is a little tricky to work with due to a Dec 22, 2021 · The blood Oxygen Concentration termed as SpO2 is measured in Percentage and Heart Beat/Pulse Rate is measured in BPM. Next, you need to download Sparkfun’s MAX30102 library. The MAX30102 belongs to the MAX3010x series of optical sensors from this firm. #include <Wire. Peter. I have found this sensor to work best — MAX30102 Pulse Oximeter. In Our previous project, we made Sep 23, 2021 · The MAX30102 is a combined pulse oximetry and heart rate sensor interface designed for small wearables or personal health monitoring devices. py and then upload . This sensor modules communicates via I2C communication protocol. yash_7200 March 14, 2024, 4:18am 1. Access the content of this video from below link:htt In this project we will connect MAX30100, an intergrated pulse oximetry and heart-rate monitor sensor from Maxim Integrated with NodeMCU, an ESP8266 board. MAX30102 provides a complete-system solution to ease the design-in-process for mobile and wearable devices. Jan 24, 2022 · MAX30102 sensor integration with ESP8266 for wifi/bluetooth capabilities - wottreng/MAX30102-heart-rate-and-blood-oxygen-level อุปกรณ์ที่ต้องใช้ใน สอนใช้งาน ESP32 MAX30102 เซ็นเซอร์วัดอัตราการเต้นของหัวใจ ชีพจร. You just attach the sensor to your fingertip and you will be able to view SPO2 (oxygen saturation) and Heart Rate (BPM) Readings on a smartphone in just a few seconds. Sensors that measure heart rate, respiration rate, blood pressure, and body temperature in real-time are integrated with ESP8266 inside a mask to monitor vital parameters. You can assemble the device exactly as shown in the figure below. In our previous project, we have made an IoT-based Pulse oximeter in which Pulse rate and Sp02 The MAX30102 is an integrated pulse oximetry and heart-rate monitor module. google. (-999) when SpO2 isn't valid, there is no other negative No. ESP32 NodeMCU ESP-WROOM-32 Wi-Fi and Bluetooth Module Dual Core Consumption CP2102 Apr 21, 2022 · Abstract. 32-bits FIFO makes MAX30102 faster than MAX30100. Sep 15, 2021 · Here is a part for the MakerFocus-MAX30102. but when put together the sensor does not work as usual and Mar 23, 2023 · https://robotronik. in___lets connect____🄸🄽🅂🅃🄰🄶🅁🄰🄼https://www. Arduino UNO will not be able to run the Maxim Algorithm due to General Description. Oct 5, 2021 · ¿Quiere aprender a medir tu ritmo cardiaco y tu saturación de oxigeno? entonces quedate a ver el video completosigueme en mis redes sociales Facebook: htt Max30100 ESP8266 Nodemcu Code 2: The following code is the modified version of the code given above. Download scientific diagram | MAX30102 sensor configuration settings as set in the NodeMCU microcontroller firmware. With this in mind, we have developed an IOT based portable and cost-efficient heart rate and SpO2/level sensor device with efficient performance. com/?code=Htoeletric4-layer PCB - 12$ : https://www. Code And Circuit Diagram:- https:/ Apr 16, 2022 · How to fix pulse oximeter module . The circuit diagram & connection is given below. The MAX30102 is an integrated pulse oximetry and heart-rate monitor biosensor module. Sensor readings gets send from MAX30102 to the ESP32, where pulse and saturation values are calculated and stored in microcontroller SRAM memory. We will display the SpO2 and BPM value in 0. The purpose of this code is to send the Blood Oxygen SpO2 and BPM values to the computer serial monitor and also to the Blynk application. Sep 14, 2022 · In this project, you will learn to make ESP32 based MAX30100 Pulse Oximeter Webserver. There are many poor quality boards which do not confirm to Maxims specs and will give incorrect values and may not work. So connect its SDA pin to D21 & SCL pin to D22 of ESP32 Board. Please check wiring/power. I want it to give readings when its valid and waiting when it's not valid. Heart beatSensor with Arduino, Heart Jun 1, 2021 · We would like to show you a description here but the site won’t allow us. Oct 15, 2020 · สอนใช้งาน ESP8266 MAX30102 เซ็นเซอร์วัดอัตราการเต้นของหัวใจ ชีพจรhttps May 17, 2021 · The MAX30102 sensor runs at 1. However, the green model uses 3. So, the wiring is very simple. If you will study the code, you will find that both the codes are exactly the same, exact the libraries MAX30102 Pulse Oximeter: Any MAX30102 sensor will work, but make sure the sensor and the I2C Signals work on right voltages. Firstly, We will discuss the introduction, pinout, working, and connection diagram of the pulse sensor (SEN-11574) with ESP8266 NodeMCU. this is the code used: Sep 13, 2016 · The Analog Devices MAX30102 includes internal LEDs, photodetectors, optical elements, and low-noise electronics with ambient light rejection. Each HC-SR04 module includes an ultrasonic transmitter, a receiver and a control circuit. This highly sensitive device operates on a single 1. The MAX30100 has I2C Pins. Readings are taken at preset intervals and stored in SPIFFS flash memory of the NodeMCU, which can be read later. SparkFun MAX30102 library: Download here from Github or Download here. esclabs. After that, when Learn about MAX 30102 Heart Beat Sensor and how to use it. The problem I’m having when putting the two sensors together doesn’t work. It is easy to build and can be used to understand how it works. 3 logic levels and so you'll need to have logic level shifters to safely use it with Arduino. This module has a pair of LEDs ( L ight E mitting D iode) that emit a monochromatic red Mar 22, 2023 · I am using MAX30102 sensor and Nodemcu ESP8266 in order to manage the data of the sensor by storing the IR and RED readings in an open array, which allows me to transmit it to FIREBASE in one go. for MAX30101/MAX30102 EV Kits . Arduino UNO will not be able to run the Maxim Algorithm Jan 8, 2013 · Program Example8_SPO2 compiled successfully and got uploaded to Wemos D1 Mini. 1 Like. Sep 14, 2022 · In this project, you will learn to make MAX30100 Pulse Oximeter Webserver using NodeMCU ESP8266. As we all know, to communicate with the sensor we need to connect the I2C line which are A5 and A4 of the Arduino board to the sensor board. Sep 11, 2021 · I&#39;m new in using arduino IDE and I have a code for Pulse Oximeter Max30100, NodeMCU ESP8266 and OLED screen, but I have Pulse Oximeter Max30102 -it was available is market- instead of Max30100. to build an efficient heartbeat and oxygen saturation device. MAX_BPM_OLED_Buzzer. even though if you run the sensors one by one it goes well and can be displayed on blynk. MAX30102 is a highly sensitive bio sensor which can used to get various human health parameters li The MAX30102 is an integrated pulse oximetry and heart-rate monitor biosensor module based on PPG ( (PhotoPlethysmoGraphy). technolab creation. arduino. NodeMCU ESP8266 adalah modul mikrokontroler yang mencakup . The sample rate for the data is set to 50 samples per second. I seek to understand if it is possible to Oct 25, 2021 · The project is simple and easy to build. May 12, 2022 · MAX30102 Pulse Oximeter has shown to be the most reliable sensor. Max30102 integrates a red LED and infrared LED, photodetecto Max30102 integrates a red LED and infrared LED, photodetector, optical device, and low-noise electronic circuit with ambient light suppression. Abstract . The Circuit assembly for this IoT Pulse oximeter is very simple. Using ArduinoSensors. The MAX30102 is an integrated pulse oximetry and heart-rate monitor module. Our previous project was based on ESP8266 NodeMCU where we monitor the @PCBWay Get 10 PCBs at just $5 on https://www. The MAX30102 does not turn on and the light also doesn't work. Compared to other components on the market, the MAX30102 is the first to integrate the following features and components into a single package with a small SMD footprint: Sep 10, 2018 · 試み MAX30102 というPulse Ox Sensorを利用して、脈拍と酸素濃度を測る試み。 MAX30100の実例が多いが、MAX30102の実例が少ない。 プログラム 「参考1」のSparkFunのライブラリを利用する。そのライブラリはMAX30105(R,G,IR LED)用だが、MAX30102(欠Green LED)でも利用できる。 OLED表示するため、「参考2」の An OLED (organic light-emitting diode) is used frequently in displaying texts, bitmap images, shapes, and different types of clocks. It uses a non-invasive method to measure oxygen saturation levels in the blood. The MAX30102 provides a complete system solution to ease the design-in process for mobile and wearable devices. 3v and GND pins. probots. In the project, when you measure your heart rate and blood oxygen concentration, press the button and your current heart rate and blood oxygen concentration will appear on the OLED screen. Are there any solutions? Aug 21, 2022 · We will now interface MAX30100 Pulse Oximeter with ESP32 . Arduino UNO will not be able to run the Maxim Algorithm due to memory limitations. 2. The bracelet consists of MAX30102 pulse and saturation sensor as well as ESP32 microcontroller. It is easily used with microcontrollers such as Arduino, ESP32, NodeMCU, etc. Nov 3, 2021 · 11:48:31. Thesis project where bracelet to measure pulse and saturation was created. 8V power supply and a separate 5. This sensor is connected with ESP8266 NodeMCU which will act as a Web Server. So, Interface the I2C pins (SCL &SDA) oximeter modules with D1 and D2 pins of NodeMCU. The MAX30102 sensor is the further optimized version of MAX30100 sensor; used as both a heart rate monitor and a pulse oximeter. Both OLED display and MAX30100 Oximeter Sensor works with the I2C. Copy the code given below and save it. It combines two LEDs, a photodetector, optimized optics, and low-noise analog signal processing to detect pulse oximetry and heart-rate signals. other than this, but I don't like that. melalui jaringan internet. 2 * It's displays the Average BPM on the screen, with an animation and a buzzer sound. I noticed a thing that when I was working with both sensor individually then both of them were working fine but when I started them using together then both of them were not working. Connect the INT pin to the NodeMCU D0 pin. Wire connection is as below: WeMos D1 -> MAX30102 5V Vin G Gnd D1 SCL D2 SDA GND IRD (Without this my IR Led does light up) When I r Feb 17, 2023 · This video talks about the circuit of the blood oxygen and heart beat monitor using NodeMCU and MAX30102. Apr 18, 2024 · First let’s start with a very basic circuit diagram. in/how-to-build-a-wifi-smart-oximeter-using-max30102-and-esp32 Aug 23, 2021 · First of all, by utilizing a soldering iron, I attached headers (female), a MAX30102 pulse oximeter sensor, a button (6x6), a 5mm common anode RGB LED, 220Ω resistors, and a power jack. At first, we will take a look at the 0. 1. Below are the item used in In this tutorial, we will learn to monitor heart rate using a pulse sensor (SEN-11574) and ESP8266 NodeMCU. 96-inch OLED display, its pinout, connections with the ESP8266 board, and then use Arduino IDE to The sensor MAX30102, produced by Maxim Integrated, is an integrated device that combines the functionalities of a heart rate monitor and an oximeter. 564 -> MAX30102 was not found. Its led needs 3. During I2C communication, other sensors fail or have wrong voltage on the communication lines. 8 #buzzer #microcontroller #programmer #programmerlife #arduinolover #arduinolove #arduinofun#TFT #Chang UPGRADED VERSION!In this project we only use the max30102 heart rate blood oxygen sensor module. There are only four pins that you need to worry about on the HC-SR04: . for components/ moduleswww. The power supply required by MAX30100 is 3. BPM are the "beats per minute" and they are around 65-75 while resting for a normal person, athletics may have lower than that, and the Heart Rate & Spo2 Monitor System Using MAX30100 & NodeMCU ESP8266. However, the signals pins, such as SDA and SCL can get up to 6V before the sensor gets damaged. Due to memory constraints, the Arduino UNO will not be able to perform the Maxim Algorithm. 5K subscribers. ino. You only need two components — ESP32 and a MAX30102 Sensor. RCWL-0530. It is so small that you can just wear it on your finger or wrist for data collecting. c) Jumper wires: for making the connections between the ESP32 and the sensor Mar 14, 2024 · About MAX30102, MLX90614 & Nodemcu-32s. install("micropython-max30102") To run the example in . com/quotesmt. 96″ OLED Display. เชื่อมต่ออุปกรณ์ตามด้านล่าง esp8266 -> max30102 • 3v3-> vin Oct 2, 2016 · We have similar guides with ESP32 and ESP8266 NodeMCU: MAX30102 Pulse Oximeter and Heart Rate Sensor with ESP32; MAX30102 Pulse Oximeter and Heart Rate Sensor with ESP8266; MAX30102 Pulse Oximeter Sensor Introduction. MAX30100 requires a non-blocking loop, while your code with all the delay(1000) and AT commands are blocking in nature. Jun 3, 2023 · Bộ đệm FIFO. i’m making a project using esp32 as well as MLX90614 and MAX30102 sensors. You can use this sensor with any microcontroller like Arduino, Raspberry Pi, ESP8266, or ESP32 and easily measure the patient Mar 30, 2021 · MAX30102 is an integrated pulse oximetry and heart-rate monitoring module. MAX30100 Pulse Oximeter. pcbway. However, during operation, I observed that the sensor disconnects once the readings reach 300. my/sensor-heart-rate-max30100-max30102 Mar 6, 2021 · This is the HC-SR04 ultrasonic distance sensor. The pullup resistors on most modules can get in the way, as you mentioned. circuit. com/edison_science Mar 25, 2024 · The MAX30102 is a very versatile sensor and it can also measure body temperature other than heart rate and blood oxygen level. GRenken September 16, 2021, 5:31pm These features are enabled by the construction of this sensor which consists of two LEDs, a photodetector, optimized optics, and low noise signal processing components. SP02 and heart-rate are computed 25 times per second using Robert Fraczkiewicz's procedure. \n Materials required: \n \n; ESP8266 like NodeMCU. Bộ đệm FIFO trong cảm biến nhịp tim và oxy trong máu MAX30102 được sử dụng để lưu trữ các mẫu dữ liệu nhịp tim và mức độ oxy huyết trong máu mà cảm biến đo được. This economical sensor provides 2cm to 400cm of non-contact measurement functionality with a ranging accuracy that can reach up to 3mm. Dec 1, 2021 · Alsofila10 December 1, 2021, 7:34pm 1. 16K views 2 years ago #heartbeat. Feb 8, 2022 · MAX30102 is capable of storing digital output as 32-deep FIFO data within the IC, while MAX30100 has 16-deep FIFO. com/?code=Htoeletric MAX_BPM_OLED_Buzzer. Jan 16, 2021 · Hey Friends In This Video I Will Show You How To Make Smart IoT Based Smart Pulse Oximeter With NodeMCU & MAX30100 Sensor. Feb 5, 2019 · Hey, in this tutorial I'm using MAX30102 High-Sensitivity Pulse Oximeter and Heart-Rate Biosensor for Fitness & Healthcare with Arduino UNO board and I add a Jun 30, 2021 · error=1; Expected Output: The values of MAX30100 and LM35 should be displayed on Serial monitor and uploaded to ThingSpeak platform. nextpcb. This sensor can easily be used with a microcontroller such as Arduino. b) ESP32 NodeMCU Board: Use ESP32 Only. Adafruit OLED SSD1306 library: Download here from Github or Download here. com. So, Interface the I2C pins (SCL &SDA) of both modules with D21 and D22 pins of ESP32. Now choose Sheets in the right sidebar. h>. I am using Nodemcu-32s with MAX30102 & MLX90614. from publication: A Comparison of Reflective Photoplethysmography for Detection วิธีการต่ออุปกรณ์ สอนใช้งาน esp8266 max30102 เซ็นเซอร์วัดอัตราการเต้นของหัวใจ ชีพจร ข้อมือ. GY-MAX30100. Moreover, a user-friendly graphic Mar 12, 2024 · If your MicroPython version supports upip package manager, put these lines after the setup of an Internet connection: import upip upip. Open your Arduino IDE and go to File > New to open a new file. ESP32 NodeMCU Board: Use ESP32 Only. With each beat, the display value is changed in the OLED screen. esp32 pulse-oximeter max30102. Jan 14, 2020 · NextPCB offers first 2-layer 100 X 100 mm PCB with 0$ : https://www. For this project, the ESP32 board will be programmed using the Arduino core. Description. It measures acceleration on the x, y and z axis as well as angular velocity. You can use this sensor with any microcontroller like Arduino, ESP8266, or ESP32 and easily measure the patient’s health Thesis project where bracelet to measure pulse and saturation was created. Jul 12, 2021 · The MAX30102 communicates via I2C, so to use the black model with an Arduino, just connect it like any other I2C device. Also clean up your code, it is difficult to read. We have similar guides with Arduino Uno and ESP8266 NodeMCU: MAX30102 Pulse Oximeter and Heart Rate Sensor with Arduino; MAX30102 Pulse Oximeter and Heart Rate Sensor with ESP8266; MAX30102 Pulse Oximeter Sensor Introduction. Jul 11, 2019 · Creating Google Script in Google Sheet for Data Logging. Just connect the sensor to the ESP8266 default I2C pins. 0V. Feb 9, 2024 · The MAX30100 is a Pulse Oximetry and heart rate monitor sensor solution. aspxArti Pulse Express is an efficient and versatile breakout board with integrated high-sensitivity optical sensors (MAX30102) and also a chip that does the calculations (biometric sensor hub MAX32664D). MakerFocus-MAX30102. This is a sensor designed by Analog Devices and features two LEDs (one Infrared and one Red), a photodetector, optics, and a low-noise signal processing unit to detect pulse oximetry (SpO2) and heart rate (HR) signals. com/ PCB Assembly @PCBWay at just $30 with free shipping on https://www. Communication is through a standard I 2 C-compatible interface. After that, we will three examples such as controlling LED with pulse rate, plotting data on serial Thesis project where bracelet to measure pulse and saturation was created. This module also measures temperature. The MAX30100 is a Pulse Oximetry and heart rate monitor sensor solution. They offer good view angles and pixel density in a cost-effective manner. 0V power supply for the internal LEDs. /example folder, please set your WiFi credentials in boot. 3. fzpz (10. Go to the App Icon In Top Right Corner Highlighted in Green Circle and Click on Docs. Feb 18, 2022 · Continuous monitoring is of upmost importance to manage emergency situations in healthcare. a) MAX30102 Pulse Oximeter: Any MAX30102 sensor will work, but make sure the sensor and the I2C Signals work on the right voltages. That is what the circuits make use of, but it is not nice. This sensor is mostly available in two different versions: GY-MAX30100 and RCWL-0530. co. Integrating Maxim’s MAX32664 Version D makes Pulse Express unique, with an internal algorithm that works to measure different data as you start. The SCL pin is connected with the Analog pin A5, SDA pin is connected with the Analog pin A4. Its operation is based on the variation of Oct 29, 2023 · max30102, mikrokontroler nodeMCU ESP8266 akan mengirimkan informasi tersebut ke Firebase . Ever since the COVID-19 pandemic, the necessity of new,innovative medical devices to analyse and monitor the situation has become profound. 4 KB) which appears to be what you have. NodeMCU-XD-58C-MAX30102-NTC10K-Integrated-Smart-mask \n. Component list on the PCB: A1 (Headers for Arduino Nano) ESP_1 (Headers for NodeMCU V3 LoLin ESP8266) S1 (Headers for SSD1306 OLED Screen) M_X1 (MAX30102) The MAX30102 is a Pulse Oximetry and heart rate monitor sensor solution. ADC resolution: 18 bit ADC resolution of MAX30102 makes it more sensitive to changes in IR voltages, while MAX30100 has 16 bits resolution. va yb xy wp ks pz tw bt bw kg